Determination of coronary flow reserve by digital angiography: Validation of a practical method not requiring power injection or electrocardiographic gating

Although coronary flow reserve is a well established measure of the physiologic significance off atherosclerotic stenosis, cumbersome methodology has prevented its widespread clinical application. This study evaluated a new simplified method of measuring coronary flow reserve based on indicator-dilu...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the American College of Cardiology 1990-07, Vol.16 (1), p.190-197
Hauptverfasser: Gurley, John C., Nissen, Steven E., Elion, Jonathan L., Booth, David C., DeMaria, Anthony N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Although coronary flow reserve is a well established measure of the physiologic significance off atherosclerotic stenosis, cumbersome methodology has prevented its widespread clinical application. This study evaluated a new simplified method of measuring coronary flow reserve based on indicator-dilution analysis of hand-injected digital coronary arteriograms. In five dogs, the circumflex artery was instrumented with an angiographic catheter, an electromagnetic flow probe and a pneumatic occluder. For each of 18 stenoses of varying severity, arteriograms were obtained under basal conditions and during papaverine-induced hyperemia. A pair of background-corrected arterial time-density curves was generated for each stenosis by off-line computer analysis of the circumflex artery arteriograms. Coronary flow reserve was calculated from the measured areas of the time-density curves and the known volume of contrast medium used to produce each curve. Angiographic flow reserve ranged from 0.9 to 6.1 (mean 2.99), whereas electromagnetic flow reserve ranged from 0.7 to 6.9 (mean 3.02). Angiographic and electromagnetic measurements of coronary flow reserve correlated well (r = 0.86). This study establishes that indicator-dilution analysis of 30 frames/s digital coronary arteriography permits the accurate determination of coronary flow reserve. The technique described employs hand injection of small doses of radiographic contrast medium using conventional catheters, and should be readily applicable to the study of human coronary artery disease.
ISSN:0735-1097
1558-3597
DOI:10.1016/0735-1097(90)90478-8