Biomechanical and histologic evaluations of pulley reconstructions in nonhuman primates

A2 pulleys were reconstructed in nonhuman primates using expanded polytetrafluoroethylene, woven nylon, and fascia. Biomechanical and histologic evaluations were done after death at 18 weeks. Tendons were normal after all pulley reconstructions. Polytetrafluoroethylene had a greater breaking strengt...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of hand surgery (American ed.) 1990-01, Vol.15 (1), p.57-63
Hauptverfasser: Dunlap, Janet, McCarthy, John A., Joyce, Michael E., Manske, Paul R.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A2 pulleys were reconstructed in nonhuman primates using expanded polytetrafluoroethylene, woven nylon, and fascia. Biomechanical and histologic evaluations were done after death at 18 weeks. Tendons were normal after all pulley reconstructions. Polytetrafluoroethylene had a greater breaking strength than woven nylon or fascia, or control pulleys, both at 18 weeks and before implantation. Histologic analyses revealed fibrous ingrowth of host tissues, no adhesions, no trauma to underlying flexor tendons, and the absence of an inflammatory response, for all pulley types.
ISSN:0363-5023
1531-6564