A clinical comparison of indices of pulmonary gas exchange with changes in the inspired oxygen concentration
Several indices have been introduced as convenient alternatives to calculation of the physiological shunt fraction (Qs/QT) for the assessment of pulmonary gas exchange. These include: the arterial-alveolar oxygen tension ratio (a/APO2), the arterial oxygen tension-inspired oxygen concentration ratio...
Gespeichert in:
Veröffentlicht in: | Canadian journal of anesthesia 1990, Vol.37 (1), p.69-76 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Several indices have been introduced as convenient alternatives to calculation of the physiological shunt fraction (Qs/QT) for the assessment of pulmonary gas exchange. These include: the arterial-alveolar oxygen tension ratio (a/APO2), the arterial oxygen tension-inspired oxygen concentration ratio (PaO2/FIO2), the respiratory index (RI), [A-a)DO2/PaO2) and the alveolar-arterial oxygen tension difference [A-a)Do2). These indices are in use clinically despite the fact that they may not accurately predict gas exchange in situations where FIO2, Qs/QT or arterial-venous oxygen content is changing. The clinical stability of each of these indices, relative to the behaviour of the physiological shunt, was therefore investigated prospectively in ten mechanically ventilated postoperative adults as FIO2 was varied from 0.30 to 1.00. None of the indices studied reliably reflected the behaviour of the physiological shunt. As FIO2 was increased incrementally from 0.30 to 1.00, 42 to 55 per cent of the measured changes in these indices were opposite in direction to the corresponding changes in the physiological shunt. The maximum magnitudes of the opposite changes were substantial; 24 and 22 per cent for the a/APO2 and PaO2/FIO2 ratio respectively, 67 per cent for the RI and 101 per cent for the (A-a)DO2. We conclude that the use of any of these indices for clinical assessment of a patient's gas exchange defect when FIO2 is varying can be substantially misleading. |
---|---|
ISSN: | 0832-610X 1496-8975 |
DOI: | 10.1007/BF03007487 |