Retrospective analysis of plate fixation of diaphyseal fractures of the forearm bones
A total of 133 fractures of the forearm bones treated by stainless steel plating have been reviewed. Technical error is the main cause of non-union. Although a union rate of 94.7 per cent was achieved, closer examination of the material shows that the stability of fixation is important in achieving...
Gespeichert in:
Veröffentlicht in: | Injury 1989-07, Vol.20 (4), p.211-214 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A total of 133 fractures of the forearm bones treated by stainless steel plating have been reviewed. Technical error is the main cause of non-union. Although a union rate of 94.7 per cent was achieved, closer examination of the material shows that the stability of fixation is important in achieving early consolidation. |
---|---|
ISSN: | 0020-1383 1879-0267 |
DOI: | 10.1016/0020-1383(89)90114-9 |