Thromboembolism from undersized Dacron grafts in the descending thoracic aorta

Three patients were referred to our institution for major thromboembolic complications secondary to the use of undersized Dacron grafts (14, 16, and 18 mm) in the descending thoracic aorta. The progressive accumulation of thrombotic material in the prosthesis caused recurrent coarctation in 1 patien...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 1989-11, Vol.48 (5), p.686-688
Hauptverfasser: Verdant, Alain, Pagé, Arthur, Baillot, Richard
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Three patients were referred to our institution for major thromboembolic complications secondary to the use of undersized Dacron grafts (14, 16, and 18 mm) in the descending thoracic aorta. The progressive accumulation of thrombotic material in the prosthesis caused recurrent coarctation in 1 patient and peripheral embolisms in the other 2. With a 9-mm Gott shunt providing distal perfusion, excision of the clotted graft and its replacement with a 22-mm Dacron prosthesis was successfully achieved in each patient.