Use of pericardium to control bleeding after ascending aortic graft replacement
We present the case of a patient who required replacement of an ascending aortic composite graft for endocarditis complicated by uncontrollable bleeding from the proximal anastomotic site. A new method of creating a right atrial-to-periprosthetic space fistula with autologous pericardium was used wi...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 1989-11, Vol.48 (5), p.706-708 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We present the case of a patient who required replacement of an ascending aortic composite graft for endocarditis complicated by uncontrollable bleeding from the proximal anastomotic site. A new method of creating a right atrial-to-periprosthetic space fistula with autologous pericardium was used with a favorable result. |
---|---|
ISSN: | 0003-4975 1552-6259 |
DOI: | 10.1016/0003-4975(89)90798-4 |