Emergent stent placement for acute Blalock-Taussig shunt obstruction after stage 1 Norwood surgery
A neonate underwent a stage 1 Norwood surgery for hypoplastic left heart syndrome and subsequently developed profound cyanosis and hemodynamic instability. Catheterization revealed an occluded modified Blalock-Taussig shunt. Angioplasty and stent implantation resulted in immediate angiographic and c...
Gespeichert in:
Veröffentlicht in: | Catheterization and cardiovascular diagnosis 1997-10, Vol.42 (2), p.191-194 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A neonate underwent a stage 1 Norwood surgery for hypoplastic left heart syndrome and subsequently developed profound cyanosis and hemodynamic instability. Catheterization revealed an occluded modified Blalock-Taussig shunt. Angioplasty and stent implantation resulted in immediate angiographic and clinical improvement, which has persisted at 5-month follow-up. This therapy may provide lifesaving treatment in selected patients. |
---|---|
ISSN: | 0098-6569 |
DOI: | 10.1002/(SICI)1097-0304(199710)42:2<191::AID-CCD21>3.0.CO;2-Q |