Use of B-Mode, Linear Array Ultrasonography for Evaluating the Technique of Bovine Artificial Insemination
B-Mode, linear array ultrasonography was used to evaluate the site of semen deposition in live cows. The insemination sheath was modified to hold a brass bead that was deposited at the simulated site of semen deposition. The position of the bead was identified by ultrasonography and the bead was rec...
Gespeichert in:
Veröffentlicht in: | Journal of dairy science 1989-08, Vol.72 (8), p.2198-2202 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | B-Mode, linear array ultrasonography was used to evaluate the site of semen deposition in live cows. The insemination sheath was modified to hold a brass bead that was deposited at the simulated site of semen deposition. The position of the bead was identified by ultrasonography and the bead was recovered by pulling a nylon line that was attached to the bead. An ultrasound technician identified placement of the bead in the site designated for semen deposition by a skilled inseminator in 24 of 25 cases. This procedure improves methods for inseminator training by providing a method of evaluating insemination technique using live animals rather than excised reproductive tracts. The ultrasound equipment used for inseminator evaluation is affordable, portable, and does not pose a human health risk. |
---|---|
ISSN: | 0022-0302 1525-3198 |
DOI: | 10.3168/jds.S0022-0302(89)79346-2 |