D-Dimer and Anticoagulation in Patients With Mechanical Prosthetic Heart Valves: A 2-Year Follow-up

The best anticoagulation level in patients with mechanical heart valve prostheses is still being debated. D-dimer, which detects the presence of cross-linked fibrin degradation products, has been demonstrated to be a useful marker of coagulation activation. This study was designed to verify whether...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Arteriosclerosis, thrombosis, and vascular biology thrombosis, and vascular biology, 1997-07, Vol.17 (7), p.1320-1324
Hauptverfasser: Giansante, Carlo, Fiotti, Nicola, Calabrese, Salvatore, La Verde, Rosa, Pandullo, Claudio, Scardi, Sabino, Guarnieri, Gianfranco
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The best anticoagulation level in patients with mechanical heart valve prostheses is still being debated. D-dimer, which detects the presence of cross-linked fibrin degradation products, has been demonstrated to be a useful marker of coagulation activation. This study was designed to verify whether heart valve prostheses in anticoagulated patients are associated with abnormalities in D-dimer plasma levels, and if so, whether such levels are related to the anticoagulation level and/or whether they could be predictive of acute vascular or hemorrhagic events. In 132 patients with single and 10 with double mechanical valve replacement, international normalized ratio (INR) and D-dimer plasma levels were determined. The INR levels of the previous 8 months were reviewed to assess the time that each patient spent in the therapeutic range. The D-dimer plasma levels were compared with those obtained from 102 matched control subjects. The patients were then followed up for 2 years to record acute vascular and hemorrhagic events. For the entire group, D-dimer plasma levels in patients were the same as those in the control group. Patients with double valve replacement had higher D-dimer plasma levels than either monovalvular implant patients or control subjects. Patients who had spent < 75% of the time within the assigned anticoagulation range had higher values for D-dimer plasma levels (median, 270 vs 198 ng/mL, P = .02). The major determinants of D-dimer plasma levels were age (R = .07, P = .009) and the percentage of time spent below the predetermined INR level (R () = .09, P = .001). During follow-up, 19 acute vascular and 16 hemorrhagic events occurred. High D-dimer tertile was the only parameter predicting the occurrence of thromboembolic events. In patients with mechanical heart valve prostheses, the D-dimer plasma level depended on the thoroughness of anticoagulation. Patients in the upper tertile of D-dimer values have an [nearly =] 5-fold risk of vascular thromboembolic events. D-dimer determination can therefore be useful in detecting patients who are at a higher risk of severe vascular events. (Arterioscler Thromb Vasc Biol. 1997;17:1320-1324.)
ISSN:1079-5642
1524-4636
DOI:10.1161/01.ATV.17.7.1320