Electrocoagulation of the endometrium with the ball-end resectoscope
Thermal destruction of the endometrium for treatment of dysfunctional uterine bleeding was accomplished with a urologic resectoscope with ball-end electrode in 15 patients. After at least 6 months of follow-up, ten experienced amenorrhea and four hypomenorrhea. One failure occurred; the patient unde...
Gespeichert in:
Veröffentlicht in: | Obstetrics and gynecology (New York. 1953) 1989-09, Vol.74 (3), p.425-427 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Thermal destruction of the endometrium for treatment of dysfunctional uterine bleeding was accomplished with a urologic resectoscope with ball-end electrode in 15 patients. After at least 6 months of follow-up, ten experienced amenorrhea and four hypomenorrhea. One failure occurred; the patient underwent vaginal hysterectomy 4 months after the procedure and was found to have adenomyosis. |
---|---|
ISSN: | 0029-7844 1873-233X |