Measurement of retinal blood velocity and flow rate in primates using a liposome-dye system

A recently developed liposome-dye method was used to make quantitative measurements of blood velocity and volumetric flow rates in the retina of the rhesus monkey. After systemic injection of a liposome-encapsulated fluorescent dye (calcein), the release of a bolus of the dye in the retina was trigg...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Ophthalmology (Rochester, Minn.) Minn.), 1989-06, Vol.96 (6), p.905-912
Hauptverfasser: KHOOBEHI, B, PEYMAN, G. A, NIESMAN, M. R, ONCEL, M
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A recently developed liposome-dye method was used to make quantitative measurements of blood velocity and volumetric flow rates in the retina of the rhesus monkey. After systemic injection of a liposome-encapsulated fluorescent dye (calcein), the release of a bolus of the dye in the retina was triggered by an ophthalmic argon laser. Initially, calcein was entrapped at a high concentration and the fluorescence of the dye in the lipid vesicle was quenched. After laser exposure, the liposomes released a bolus of dye at the laser exposure site in a specific vessel of the retina. The released dye formed a well-defined, fluorescent wavefront in the exposed artery or vein. By measuring the distance the dye traveled in the vein over a set time interval, it was possible to measure blood velocity in retinal vessels of various diameters, and to calculate volumetric flow rates in those vessels.
ISSN:0161-6420
1549-4713