Routine determination of radiochemical purity of 99mTc-MIBI

The manufacturer recommends that the radiochemical purity of 99mTc-MIBI be determined with alumina TLC plates developed in ethanol, but for routine use this is slow and requires care. After comparing a variety of systems, we obtained equivalent results using ITLC-SG strips developed with saline to d...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes Applied radiation and isotopes, 1989, Vol.40 (1), p.95-97
Hauptverfasser: Proulx, Annette, Ballinger, James R., Gulenchyn, Karen Y.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 97
container_issue 1
container_start_page 95
container_title International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes
container_volume 40
creator Proulx, Annette
Ballinger, James R.
Gulenchyn, Karen Y.
description The manufacturer recommends that the radiochemical purity of 99mTc-MIBI be determined with alumina TLC plates developed in ethanol, but for routine use this is slow and requires care. After comparing a variety of systems, we obtained equivalent results using ITLC-SG strips developed with saline to determine [ 99mTc]pertechnetate and with acetone to determine 99mTc colloid; % 99mTc-MIBI was determined by difference from 100%. These separations are the opposite of those obtained with the routine polar 99mTc radiopharmaceuticals. Equivalent results were obtained even more rapidly by extracting 99mTc-MIBI from water into chloroform.
doi_str_mv 10.1016/0883-2889(89)90182-2
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_78956006</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>0883288989901822</els_id><sourcerecordid>78956006</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2047-2c18930de94f34ad42cc77a58bcaf85760e2b0bda63eb5fd88b35db89d956f4b3</originalsourceid><addsrcrecordid>eNp9kFtLAzEQhfOg1Fr9Bwr7JPqwmmRvCYKgxUuhIkh9DrlMMLK7qcmu0H_vri19FAYGzpw5w3wInRF8TTApbzBjWUoZ45eMX3FMGE3pAZru5SN0HOMXxpTyik7QhBY5JrSaott333euhcRAB6FxreycbxNvkyCN8_oTGqdlnaz74LrNqHPerHT6unhYnKBDK-sIp7s-Qx9Pj6v5S7p8e17M75eppjivUqoJ4xk2wHOb5dLkVOuqkgVTWlpWVCUGqrAyssxAFdYwprLCKMYNL0qbq2yGLra56-C_e4idaFzUUNeyBd9HUbHBiHE5GPOtUQcfYwAr1sE1MmwEwWLkJEYgYgQihvrjJOiwdr7L71UDZr-0gzTM77ZzGJ78cRBE1A5aDcYF0J0w3v1_4BeX73iQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>78956006</pqid></control><display><type>article</type><title>Routine determination of radiochemical purity of 99mTc-MIBI</title><source>MEDLINE</source><source>Alma/SFX Local Collection</source><creator>Proulx, Annette ; Ballinger, James R. ; Gulenchyn, Karen Y.</creator><creatorcontrib>Proulx, Annette ; Ballinger, James R. ; Gulenchyn, Karen Y.</creatorcontrib><description>The manufacturer recommends that the radiochemical purity of 99mTc-MIBI be determined with alumina TLC plates developed in ethanol, but for routine use this is slow and requires care. After comparing a variety of systems, we obtained equivalent results using ITLC-SG strips developed with saline to determine [ 99mTc]pertechnetate and with acetone to determine 99mTc colloid; % 99mTc-MIBI was determined by difference from 100%. These separations are the opposite of those obtained with the routine polar 99mTc radiopharmaceuticals. Equivalent results were obtained even more rapidly by extracting 99mTc-MIBI from water into chloroform.</description><identifier>ISSN: 0883-2889</identifier><identifier>DOI: 10.1016/0883-2889(89)90182-2</identifier><identifier>PMID: 2540127</identifier><language>eng</language><publisher>England: Elsevier B.V</publisher><subject>Chromatography, Thin Layer ; Nitriles - isolation &amp; purification ; Nitriles - standards ; Organometallic Compounds - isolation &amp; purification ; Organometallic Compounds - standards ; Silica Gel ; Silicon Dioxide ; Technetium Tc 99m Sestamibi</subject><ispartof>International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1989, Vol.40 (1), p.95-97</ispartof><rights>1988</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2047-2c18930de94f34ad42cc77a58bcaf85760e2b0bda63eb5fd88b35db89d956f4b3</citedby><cites>FETCH-LOGICAL-c2047-2c18930de94f34ad42cc77a58bcaf85760e2b0bda63eb5fd88b35db89d956f4b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,4025,27928,27929,27930</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2540127$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Proulx, Annette</creatorcontrib><creatorcontrib>Ballinger, James R.</creatorcontrib><creatorcontrib>Gulenchyn, Karen Y.</creatorcontrib><title>Routine determination of radiochemical purity of 99mTc-MIBI</title><title>International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes</title><addtitle>Int J Rad Appl Instrum A</addtitle><description>The manufacturer recommends that the radiochemical purity of 99mTc-MIBI be determined with alumina TLC plates developed in ethanol, but for routine use this is slow and requires care. After comparing a variety of systems, we obtained equivalent results using ITLC-SG strips developed with saline to determine [ 99mTc]pertechnetate and with acetone to determine 99mTc colloid; % 99mTc-MIBI was determined by difference from 100%. These separations are the opposite of those obtained with the routine polar 99mTc radiopharmaceuticals. Equivalent results were obtained even more rapidly by extracting 99mTc-MIBI from water into chloroform.</description><subject>Chromatography, Thin Layer</subject><subject>Nitriles - isolation &amp; purification</subject><subject>Nitriles - standards</subject><subject>Organometallic Compounds - isolation &amp; purification</subject><subject>Organometallic Compounds - standards</subject><subject>Silica Gel</subject><subject>Silicon Dioxide</subject><subject>Technetium Tc 99m Sestamibi</subject><issn>0883-2889</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1989</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNp9kFtLAzEQhfOg1Fr9Bwr7JPqwmmRvCYKgxUuhIkh9DrlMMLK7qcmu0H_vri19FAYGzpw5w3wInRF8TTApbzBjWUoZ45eMX3FMGE3pAZru5SN0HOMXxpTyik7QhBY5JrSaott333euhcRAB6FxreycbxNvkyCN8_oTGqdlnaz74LrNqHPerHT6unhYnKBDK-sIp7s-Qx9Pj6v5S7p8e17M75eppjivUqoJ4xk2wHOb5dLkVOuqkgVTWlpWVCUGqrAyssxAFdYwprLCKMYNL0qbq2yGLra56-C_e4idaFzUUNeyBd9HUbHBiHE5GPOtUQcfYwAr1sE1MmwEwWLkJEYgYgQihvrjJOiwdr7L71UDZr-0gzTM77ZzGJ78cRBE1A5aDcYF0J0w3v1_4BeX73iQ</recordid><startdate>1989</startdate><enddate>1989</enddate><creator>Proulx, Annette</creator><creator>Ballinger, James R.</creator><creator>Gulenchyn, Karen Y.</creator><general>Elsevier B.V</general><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1989</creationdate><title>Routine determination of radiochemical purity of 99mTc-MIBI</title><author>Proulx, Annette ; Ballinger, James R. ; Gulenchyn, Karen Y.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2047-2c18930de94f34ad42cc77a58bcaf85760e2b0bda63eb5fd88b35db89d956f4b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1989</creationdate><topic>Chromatography, Thin Layer</topic><topic>Nitriles - isolation &amp; purification</topic><topic>Nitriles - standards</topic><topic>Organometallic Compounds - isolation &amp; purification</topic><topic>Organometallic Compounds - standards</topic><topic>Silica Gel</topic><topic>Silicon Dioxide</topic><topic>Technetium Tc 99m Sestamibi</topic><toplevel>online_resources</toplevel><creatorcontrib>Proulx, Annette</creatorcontrib><creatorcontrib>Ballinger, James R.</creatorcontrib><creatorcontrib>Gulenchyn, Karen Y.</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Proulx, Annette</au><au>Ballinger, James R.</au><au>Gulenchyn, Karen Y.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Routine determination of radiochemical purity of 99mTc-MIBI</atitle><jtitle>International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes</jtitle><addtitle>Int J Rad Appl Instrum A</addtitle><date>1989</date><risdate>1989</risdate><volume>40</volume><issue>1</issue><spage>95</spage><epage>97</epage><pages>95-97</pages><issn>0883-2889</issn><abstract>The manufacturer recommends that the radiochemical purity of 99mTc-MIBI be determined with alumina TLC plates developed in ethanol, but for routine use this is slow and requires care. After comparing a variety of systems, we obtained equivalent results using ITLC-SG strips developed with saline to determine [ 99mTc]pertechnetate and with acetone to determine 99mTc colloid; % 99mTc-MIBI was determined by difference from 100%. These separations are the opposite of those obtained with the routine polar 99mTc radiopharmaceuticals. Equivalent results were obtained even more rapidly by extracting 99mTc-MIBI from water into chloroform.</abstract><cop>England</cop><pub>Elsevier B.V</pub><pmid>2540127</pmid><doi>10.1016/0883-2889(89)90182-2</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0883-2889
ispartof International journal of radiation applications and instrumentation. Part A, Applied radiation and isotopes, 1989, Vol.40 (1), p.95-97
issn 0883-2889
language eng
recordid cdi_proquest_miscellaneous_78956006
source MEDLINE; Alma/SFX Local Collection
subjects Chromatography, Thin Layer
Nitriles - isolation & purification
Nitriles - standards
Organometallic Compounds - isolation & purification
Organometallic Compounds - standards
Silica Gel
Silicon Dioxide
Technetium Tc 99m Sestamibi
title Routine determination of radiochemical purity of 99mTc-MIBI
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T11%3A27%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Routine%20determination%20of%20radiochemical%20purity%20of%2099mTc-MIBI&rft.jtitle=International%20journal%20of%20radiation%20applications%20and%20instrumentation.%20Part%20A,%20Applied%20radiation%20and%20isotopes&rft.au=Proulx,%20Annette&rft.date=1989&rft.volume=40&rft.issue=1&rft.spage=95&rft.epage=97&rft.pages=95-97&rft.issn=0883-2889&rft_id=info:doi/10.1016/0883-2889(89)90182-2&rft_dat=%3Cproquest_cross%3E78956006%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=78956006&rft_id=info:pmid/2540127&rft_els_id=0883288989901822&rfr_iscdi=true