Diffusion imaging with a multi-echo MISSTEC sequence
An imaging method is presented to measure the water‐diffusion coefficient. The sequence (MISSTEC) uses the simultaneous acquisition of a spin echo and several stimulated echoes with the same intensity except for diffusion weighting. The optimal number of stimulated echoes was calculated to minimize...
Gespeichert in:
Veröffentlicht in: | Journal of magnetic resonance imaging 1997-03, Vol.7 (2), p.399-404 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | An imaging method is presented to measure the water‐diffusion coefficient. The sequence (MISSTEC) uses the simultaneous acquisition of a spin echo and several stimulated echoes with the same intensity except for diffusion weighting. The optimal number of stimulated echoes was calculated to minimize the diffusion coefficient error (D). D values obtained in vitro and in vivo were in good agreement with those from the spin‐echo sequence (Intra Voxel Incoherent Motion [IVIM] method). The total acquisition time is half that of the classic IVIM method. |
---|---|