Can 24‐hour ambulatory blood pressure measurement predict the development of hypertension in primigravidae?

Objective To assess the role of 24‐hour ambulatory blood pressure measurement in the mid‐second trimester as a predictive test for the development of hypertension in pregnancy. Design Prospective intervention. Setting The Rotunda Hospital, Dublin. Participants One thousand one hundred and two health...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:BJOG : an international journal of obstetrics and gynaecology 1997-03, Vol.104 (3), p.356-362
Hauptverfasser: Higgins, John R., Walshe, Joseph J., Halligan, Aidan, O'Brien, Eoin, Conroy, Ronan, Darling, Michael R. N.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Objective To assess the role of 24‐hour ambulatory blood pressure measurement in the mid‐second trimester as a predictive test for the development of hypertension in pregnancy. Design Prospective intervention. Setting The Rotunda Hospital, Dublin. Participants One thousand one hundred and two healthy primigravid women. Intervention 24‐hour ambulatory blood pressure measurement at 18 to 24 weeks of gestation. Main outcome measures The development of pre‐eclampsia or gestational hypertension. Results A total of 1048 women had sufficient readings to be included in the final analysis. Of these, 23 (2.2%) developed pre‐eclampsia, 64 (6.1%) developed gestational hypertension and 961 (91.7%) remained normotensive. Significantly higher ambulatory blood pressures were recorded in both the pre‐eclamptic and gestational hypertensive group compared with the normotensive group. In addition, the gestational hypertensive group had significantly higher clinically measured blood pressure compared with the normotensive group. There were no differences between the pre‐eclamptic and the gestational hypertensive group for any of the blood pressure parameters analysed. The best overall predictor for pre‐eclampsia was 24‐hour mean diastolic pressure which using a cutoff level of 71 mmHg gave a test with a sensitivity of only 22% and a positive predictive value of 15%. Conclusion Because the absolute differences are small and the overlap between the hypertensive and normotensive groups large, ambulatory blood pressure measurement, in a healthy primigravid population, between 18 and 24 weeks of gestation is not a useful predictor of hypertension.
ISSN:1470-0328
0306-5456
1471-0528
1365-215X
DOI:10.1111/j.1471-0528.1997.tb11468.x