False-positive I-131 Whole-body Imaging After I-131 Therapy for a Follicular Carcinoma
A 57-year-old man was treated with ablative radioiodine therapy for follicular thyroid carcinoma. The post-therapeutic whole body scans detected radionuclide accumulation in the area of the right occiput at the site of a cranial defect. The defect was caused by trauma in 1964. Bone scintigraphy did...
Gespeichert in:
Veröffentlicht in: | Clinical nuclear medicine 1997-02, Vol.22 (2), p.123-124 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A 57-year-old man was treated with ablative radioiodine therapy for follicular thyroid carcinoma. The post-therapeutic whole body scans detected radionuclide accumulation in the area of the right occiput at the site of a cranial defect. The defect was caused by trauma in 1964. Bone scintigraphy did not show increased uptake in this area. Magnetic resonance imaging showed porencephaly, but it did not show a metasasis. |
---|---|
ISSN: | 0363-9762 1536-0229 |
DOI: | 10.1097/00003072-199702000-00013 |