Test-retest reliability of the MSLT
The test-retest reliability of the Multiple Sleep Latency Test (MSLT) was evaluated in 14 healthy normal subjects. Each slept a single night in the laboratory (8 h time in bed) and received the MSLT the following day (1000, 1200, 1400, and 1600 h) on two occasions separated by 4-14 months. Mean slee...
Gespeichert in:
Veröffentlicht in: | Sleep (New York, N.Y.) N.Y.), 1988-12, Vol.11 (6), p.562-565 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The test-retest reliability of the Multiple Sleep Latency Test (MSLT) was evaluated in 14 healthy normal subjects. Each slept a single night in the laboratory (8 h time in bed) and received the MSLT the following day (1000, 1200, 1400, and 1600 h) on two occasions separated by 4-14 months. Mean sleep latency (four tests) was highly reliable from MSLT to MSLT (r = 0.97, p less than 0.001). The test-retest reliability did not change as a function of the interval of time between tests or as a function of the level of sleepiness (range = 4-20 min) within the population. However, as the number of tests comprising the MSLT was reduced below three, the reliability was reduced such that only 50% or less of the variance could be predicted. |
---|---|
ISSN: | 0161-8105 1550-9109 |