Transcranial doppler measurements of the middle cerebral artery: effect of hematocrit
We evaluated the effects of hematocrit on blood velocity in the middle cerebral artery measured by transcranial Doppler ultrasonography in 45 patients. Hematocrits ranged from 16% to 46%, and systolic blood velocities ranged from 70 to 190 (mean 40 to 140) cm/sec. Decreases in hematocrit correlated...
Gespeichert in:
Veröffentlicht in: | Stroke (1970) 1988-12, Vol.19 (12), p.1466-1469 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We evaluated the effects of hematocrit on blood velocity in the middle cerebral artery measured by transcranial Doppler ultrasonography in 45 patients. Hematocrits ranged from 16% to 46%, and systolic blood velocities ranged from 70 to 190 (mean 40 to 140) cm/sec. Decreases in hematocrit correlated with increases in blood velocity in the middle cerebral artery. These results suggest that transcranial Doppler measurements made in the presence of anemia may need correction. |
---|---|
ISSN: | 0039-2499 1524-4628 |
DOI: | 10.1161/01.str.19.12.1466 |