Endoscopic resection of large pedunculated colorectal polyps using a detachable snare
Background: Colonoscopic resection of pedunculated polyps with heads 1 cm or greater in diameter is difficult because of the risk of bleeding. To minimize this complication, we used a detachable snare that allowed endoscopic ligation of the stalk of a large pedunculated polyp and evaluated its safet...
Gespeichert in:
Veröffentlicht in: | Gastrointestinal endoscopy 1996-11, Vol.44 (5), p.594-597 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background: Colonoscopic resection of pedunculated polyps with heads 1 cm or greater in diameter is difficult because of the risk of bleeding. To minimize this complication, we used a detachable snare that allowed endoscopic ligation of the stalk of a large pedunculated polyp and evaluated its safety and effectiveness in comparison with conventional endoscopic snare polypectomy.
Methods: Patients with pedunculated polyps with heads 1 cm or greater in diameter were randomly assigned to colonoscopic polypectomy with (N = 47) or without (N = 42) a detachable snare. Arterial pumping bleeding immediately after colonoscopic polypectomy or hematochezia resulting in a 10% or greater drop in hematocrit was defined as “bleeding.”
Results: No bleeding occurred during or after polypectomy with a detachable snare, but bleeding occurred significantly more frequently (five patients, 12%) without a snare. Moreover, the use of a detachable snare reduced the duration of hospitalization after polypectomy.
Conclusions: Colonoscopic polypectomy with a detachable snare may be safer than conventional polypectomy without a detachable snare for resection of large, pedunculated polyps. (Gastrointest Endosc 1996;44:594-7.) |
---|---|
ISSN: | 0016-5107 1097-6779 |
DOI: | 10.1016/S0016-5107(96)70015-9 |