The influence of size or number of biopsies on rapid urease test results: a prospective evaluation

Background: The optimal number or size of endoscopic biopsies for use in rapid urease testing has not been established. Postulating that increasing the amount of tissue sampled would improve diagnostic yield and hasten development of a positive test, we compared urease testing with one regular biops...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Gastrointestinal endoscopy 1996-01, Vol.43 (1), p.49-53
Hauptverfasser: Laine, Loren, Chun, David, Stein, Craig, El-Beblawi, Ihab, Sharma, Vishvinder, Chandrasoma, Parakrama
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background: The optimal number or size of endoscopic biopsies for use in rapid urease testing has not been established. Postulating that increasing the amount of tissue sampled would improve diagnostic yield and hasten development of a positive test, we compared urease testing with one regular biopsy, two regular biopsies, and one “jumbo” forceps biopsy. Methods: One hundred fifty patients undergoing endoscopy had three sets of prepyloric biopsies placed in a CLOtest: one regular forceps biopsy, two regular forceps biopsy, and one large-channel jumbo forceps biopsy. Biopsies were then taken for two independent histologic examinations. Disagreements were resolved by another examiner. Results: Eighty-nine patients (59%) had Helicobacter pylori infection by histology; interobserver agreement was 90% with κ = 0.78. The mean time to a positive test was 5.3 ± 0.9 hours for one regular biopsy, 3.2 ± 0.7 hours for two regular biopsies, and 3.8 ± 0.8 hours for one jumbo biopsy (p < 0.01 for two regular, one jumbo vs. one regular biopsy). Compared to one regular biopsy, the urease test was positive at least 30 minutes earlier in 56% of the patients with two regular biopsies and 54% with one jumbo biopsy. Sensitivities for one regular versus two regular biopsies were 1 hour, 19% versus 33% (p = 0.059); 2 hours, 38% versus 49% (p = 0.17); 3 hours, 48% versus 60% (p = 0.18); and 24 hours, 75% versus 79% (p > 0.20). Conclusions: Doubling the amount of tissue in the CLOtest hastens the development of a positive test by approximately 1 ½ to 2 hours; tests become positive at least 30 minutes earlier in over 50% of the patients. Low cost, ease, and excellent specificity make the rapid urease test a valuable diagnostic tool. Nevertheless, if used as a “rapid” diagnostic test (read within 3 hours of biopsy), it is associated with a false negative rate of approximately 40%. (Gastrointest Endosc 1996;43:49-53.)
ISSN:0016-5107
1097-6779
DOI:10.1016/S0016-5107(96)70260-2