Supracondylar femoral fracture above a PFC posterior cruciate-substituting total knee arthroplasty treated with supracondylar nailing. A unique technical problem

Supracondylar fracture above a total knee arthroplasty with a posterior cruciate-substituting design presents a challenging problem to the orthopaedic surgeon. The standard treatment using a intramedullary rod is made difficult by the design of the PFC cruciate-substituting total knee arthroplasty (...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 1996-08, Vol.11 (5), p.637-639
Hauptverfasser: Maniar, R N, Umlas, M E, Rodriguez, J A, Ranawat, C S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Supracondylar fracture above a total knee arthroplasty with a posterior cruciate-substituting design presents a challenging problem to the orthopaedic surgeon. The standard treatment using a intramedullary rod is made difficult by the design of the PFC cruciate-substituting total knee arthroplasty (Johnson & Johnson Orthopaedics, Raynham, MA), which prevents entry of a standard supracondylar nail to the medullary canal of the femur. A technique for using an interlocking intramedullary rod to treat a supracondylar fracture above a posterior cruciate-substituting total knee arthroplasty is described. A case is presented illustrating this technique.