Supracondylar femoral fracture above a PFC posterior cruciate-substituting total knee arthroplasty treated with supracondylar nailing. A unique technical problem
Supracondylar fracture above a total knee arthroplasty with a posterior cruciate-substituting design presents a challenging problem to the orthopaedic surgeon. The standard treatment using a intramedullary rod is made difficult by the design of the PFC cruciate-substituting total knee arthroplasty (...
Gespeichert in:
Veröffentlicht in: | The Journal of arthroplasty 1996-08, Vol.11 (5), p.637-639 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Supracondylar fracture above a total knee arthroplasty with a posterior cruciate-substituting design presents a challenging problem to the orthopaedic surgeon. The standard treatment using a intramedullary rod is made difficult by the design of the PFC cruciate-substituting total knee arthroplasty (Johnson & Johnson Orthopaedics, Raynham, MA), which prevents entry of a standard supracondylar nail to the medullary canal of the femur. A technique for using an interlocking intramedullary rod to treat a supracondylar fracture above a posterior cruciate-substituting total knee arthroplasty is described. A case is presented illustrating this technique. |
---|---|
ISSN: | 0883-5403 |
DOI: | 10.1016/S0883-5403(96)80123-9 |