Tricuspid Valve Replacement Using an Unstented Pulmonary Homograft
In consideration of the limitations of mechanical and stent-mounted tissue valves, a technique was developed for tricuspid valve replacement using an inverted pulmonary homograft. It was used successfully in a 4-year-old patient operated on for pulmonary atresia with intact ventricular septum and in...
Gespeichert in:
Veröffentlicht in: | The Annals of thoracic surgery 1988-07, Vol.46 (1), p.58-62 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In consideration of the limitations of mechanical and stent-mounted tissue valves, a technique was developed for tricuspid valve replacement using an inverted pulmonary homograft. It was used successfully in a 4-year-old patient operated on for pulmonary atresia with intact ventricular septum and in a 3 ½-year-old girl with Ebstein's anomaly. |
---|---|