Cannulation of the epidural space: a comparison of 18- and 16-gauge needles
A group of 685 obstetric patients were randomly allocated to have their epidural block performed using either a 16-gauge or an 18-gauge Tuohy needle. Bleeding was noted from needle or catheter trauma in 18% of patients and it proved impossible to insert the catheter in 3%. The majority of mothers ex...
Gespeichert in:
Veröffentlicht in: | Anaesthesia 1988-02, Vol.43 (2), p.154-155 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | A group of 685 obstetric patients were randomly allocated to have their epidural block performed using either a 16-gauge or an 18-gauge Tuohy needle. Bleeding was noted from needle or catheter trauma in 18% of patients and it proved impossible to insert the catheter in 3%. The majority of mothers experienced little discomfort during the procedure but 2% found insertion to be very uncomfortable. There was no significant difference in the complication rate, ease of use, or patient discomfort between the 18- or 16-gauge needles. Epidural analgesia, although safe, is not without hazard. It may be difficult to perform and may, rarely, cause considerable discomfort. |
---|---|
ISSN: | 0003-2409 1365-2044 |
DOI: | 10.1111/j.1365-2044.1988.tb05489.x |