Correction to "Calorimetric Measurement of the Carbon Kerma Factor for 14.6-MeV Neutrons" by J. C. McDonald
The report corrected has a serious calculation error in the compensation for the γ-ray kerma of the mixed radiation field used to make the measurements. The error is explained and the value of the carbon kerma factor for 14.6-MeV neutrons is recalculated from the experimental data. Comparison of thi...
Gespeichert in:
Veröffentlicht in: | Radiation research 1988-02, Vol.113 (2), p.396-397 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The report corrected has a serious calculation error in the compensation for the γ-ray kerma of the mixed radiation field used to make the measurements. The error is explained and the value of the carbon kerma factor for 14.6-MeV neutrons is recalculated from the experimental data. Comparison of this value to those determined by others suggests that the calorimetric technique described has a significant error. |
---|---|
ISSN: | 0033-7587 1938-5404 |
DOI: | 10.2307/3577213 |