Cardiopulmonary bypass with modified fluid gelatin and heparin-coated circuits

We have assessed the efficacy of cardiopulmonary bypass (CPB) using normal colloid oncotic pressure (COP) in a randomized, controlled study of 20 patients undergoing elective coronary artery surgery using heparin-coated circuits. For CPB, we used either crystalloid priming 1650 ml (n = 10) or colloi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:British journal of anaesthesia : BJA 1996-01, Vol.76 (1), p.13-19
Hauptverfasser: Jansen, P G, te Velthuis, H, Wildevuur, W R, Huybregts, M A, Bulder, E R, van der Spoel, H I, Sturk, A, Eijsman, L, Wildevuur, C R
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have assessed the efficacy of cardiopulmonary bypass (CPB) using normal colloid oncotic pressure (COP) in a randomized, controlled study of 20 patients undergoing elective coronary artery surgery using heparin-coated circuits. For CPB, we used either crystalloid priming 1650 ml (n = 10) or colloid priming 1650 ml (2.4% modified fluid gelatin, n = 10). While COP did not change during bypass in the colloid group, a decline was observed in the crystalloid group (P = 0.005). By the end of bypass, the decrease in COP compared with baseline (delta COP) was 8.5 (S.D. 1.1) mm Hg in the crystalloid group compared with 1.5 (2.1) mm Hg in the colloid group (P = 0.0001). delta COP correlated positively with fluid balance during bypass (r2 = 0.41, P = 0.002). Similar increments in complement factors C3b/c and C4b/c, tumour necrosis factor-alpha and neutrophil elastase, but not endotoxins, were found in both groups as indicators of a systemic inflammatory response. A clinical performance score composed of fluid balance, postoperative duration of intubation and the difference between rectal temperature and skin temperature was more favourable in patients treated with colloid priming (P = 0.03). Median postoperative hospital stay was 7 (range 5-16) days in the crystalloid group compared with 5 (4-8) days in the colloid group (P = 0.016). Regression analysis indicated that CPB time, fluid balance during operation and postoperative PO2/FlO2 ratio were independent factors that predicted postoperative hospital stay. From these preliminary results we conclude that in the absence of endotoxaemia, use of a normal COP during CPB with modified fluid gelatin in heparin-coated circuits resulted in an improved postoperative course an a reduction in hospital stay.
ISSN:0007-0912
1471-6771
DOI:10.1093/bja/76.1.13