Carbon dioxide pneumothorax in laparoscopic surgery
We conducted this animal study to investigate the cardiopulmonary effects of carbon dioxide pneumothorax during laparoscopic surgery and determine what intervention, if any, is necessary for this phenomenon. A swine animal model was used (n = 8). Animals were anesthetized and underwent peritoneal in...
Gespeichert in:
Veröffentlicht in: | The American journal of surgery 1996-05, Vol.171 (5), p.464-466 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We conducted this animal study to investigate the cardiopulmonary effects of carbon dioxide pneumothorax during laparoscopic surgery and determine what intervention, if any, is necessary for this phenomenon.
A swine animal model was used (n = 8). Animals were anesthetized and underwent peritoneal insufflation with carbon dioxide. A laceration was created in the left diaphragm. pO
2, pCO
2, oxygen saturation, peak inspiratory pressure (PIP), systolic blood presssure, and heart rate were measured and subjected to statistical analysis.
Significant changes were noted in the pO
2, O
2 saturation, pCO
2, and PIP upon creation of the pneumothorax. Trends were also noted in the heart rate and the systolic blood pressure. The physiologic changes could be corrected by noninvasive means and without terminating the procedure.
Carbon dioxide pneumothorax produces reproducible cardiopulmonary changes in laparoscopic surgery. These changes are easily monitored and the resulting cardiopulmonary changes can be treated without invasive means. |
---|---|
ISSN: | 0002-9610 1879-1883 |
DOI: | 10.1016/S0002-9610(96)00009-8 |