Application of a superparamagnetic iron oxide (Resovis®) for MR imaging of human cerebral blood volume
The authors describe the feasibility of dynamic MRI using a novel superparamagnetic iron oxide contrast agent. Resovist® was injected as a bolus at doses of 4, 8, and 16 μmol Fe/kg bodyweight in three consented patients participating in a Phase 2 clinical multicenter trial for hepatic MRI. Dynamic i...
Gespeichert in:
Veröffentlicht in: | Magnetic resonance in medicine 1995-11, Vol.34 (5), p.694-697 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The authors describe the feasibility of dynamic MRI using a novel superparamagnetic iron oxide contrast agent. Resovist® was injected as a bolus at doses of 4, 8, and 16 μmol Fe/kg bodyweight in three consented patients participating in a Phase 2 clinical multicenter trial for hepatic MRI. Dynamic images of the brain were obtained with a conventional FLASH sequence. Results were analyzed by evaluation of dynamic images, cerebral blood volume maps, and normalized signal intensity time curves. Resovist® enabled rapid injections and a dose‐dependent strong reduction in gray and white matter signal intensity. The small injection volume and good tolerability may enable Resovist® to serve as a perfusion agent. Dedicated clinical trials are warranted to assess the potentials of Resovist® for perfusion MRI and fMRI. |
---|---|
ISSN: | 0740-3194 1522-2594 |
DOI: | 10.1002/mrm.1910340507 |