A reassessment of fasting plasma glucose concentrations in population screening for diabetes mellitus in a community of northern European ancestry : the Wadena City Health Study

In current clinical and research practice, the determination of diabetic status depends largely on plasma glucose levels 2 h after the ingestion of a standard 75-g glucose load, the oral glucose tolerance test (OGTT). The OGTT, however, remains inconvenient, not highly reproducible, and costly, espe...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Acta diabetologica 1994-12, Vol.31 (4), p.187-192
Hauptverfasser: CLEMENTS, J. P, FRENCH, L. R, BOEN, J. R, SPRAFKA, J. M, HEDLUND, B, GOETZ, F. C
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In current clinical and research practice, the determination of diabetic status depends largely on plasma glucose levels 2 h after the ingestion of a standard 75-g glucose load, the oral glucose tolerance test (OGTT). The OGTT, however, remains inconvenient, not highly reproducible, and costly, especially for large-scale studies and population screening tests. Fasting plasma glucose (FPG) determinations are convenient, reliable, and valid measures of glucose intolerance, but the currently prescribed cut-off point of 140 mg/dl (7.8 mM) lacks sensitivity. We evaluated the reliability and validity of fasting plasma glucose (FPG) values compared with other measures of hyperglycemia for a diagnosis of diabetes in a population-based study of carbohydrate metabolism in Wadena, Minnesota, a community of predominantly northern European ancestry. As a part of this effort, a random sample of Wadena adults, stratified by age and gender, plus all known, previously diagnosed diabetics participated in 2 days of baseline testing and were followed prospectively and retested 5 years later. Cross-sectional analyses of baseline data are presented in this article. Diabetic status was ascertained by administering a standard OGTT according to National Diabetes Data Group (NDDG) specifications. Sensitivity and specificity levels obtained when using a FPG cut-off point of 6.4 mM were 95.2% and 97.4%, respectively. In study subjects with no known diagnosis of diabetes, the FPG cut-off point of 6.4 mM performed reasonably well with a sensitivity and specificity of 67.7% and 97.4%, respectively.
ISSN:0940-5429
1432-5233
DOI:10.1007/BF00571949