Acromial compromise with use of a transacromial portal: A biomechanical study

In an experimental evaluation with 14 paired cadaveric scapulae we found that the transacromial arthroscopy portal, used occasionally in the repair of superior labral lesions, will reduce the structural integrity of the acromion to approximately 60% (range 25% to 85%) of its original strength, there...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of shoulder and elbow surgery 1995-07, Vol.4 (4), p.249-253
Hauptverfasser: Coen, Michael J., Jobe, Christopher M., Pak, Ken
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In an experimental evaluation with 14 paired cadaveric scapulae we found that the transacromial arthroscopy portal, used occasionally in the repair of superior labral lesions, will reduce the structural integrity of the acromion to approximately 60% (range 25% to 85%) of its original strength, thereby placing it at increased risk of fracture. These studies provide baseline biomechanical information and suggest that limited shoulder activity is indicated after use of this portal
ISSN:1058-2746
1532-6500