Acromial compromise with use of a transacromial portal: A biomechanical study
In an experimental evaluation with 14 paired cadaveric scapulae we found that the transacromial arthroscopy portal, used occasionally in the repair of superior labral lesions, will reduce the structural integrity of the acromion to approximately 60% (range 25% to 85%) of its original strength, there...
Gespeichert in:
Veröffentlicht in: | Journal of shoulder and elbow surgery 1995-07, Vol.4 (4), p.249-253 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In an experimental evaluation with 14 paired cadaveric scapulae we found that the transacromial arthroscopy portal, used occasionally in the repair of superior labral lesions, will reduce the structural integrity of the acromion to approximately 60% (range 25% to 85%) of its original strength, thereby placing it at increased risk of fracture. These studies provide baseline biomechanical information and suggest that limited shoulder activity is indicated after use of this portal |
---|---|
ISSN: | 1058-2746 1532-6500 |
DOI: | 10.1016/S1058-2746(05)80016-3 |