Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter
Two cases are presented illustrating the use of a new intracoronary infusion catheter providing flow support using a unique spiral coil design. Good clinical outcomes were obtained employing 4‐hr inflations with localized infusion of urokinase at the site of dissection and extensive clot formation,...
Gespeichert in:
Veröffentlicht in: | Catheterization and cardiovascular diagnosis 1995-09, Vol.36 (1), p.67-73 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 73 |
---|---|
container_issue | 1 |
container_start_page | 67 |
container_title | Catheterization and cardiovascular diagnosis |
container_volume | 36 |
creator | Groh, William C. Kurnik, Peter B. Matthai Jr, William H. Untereker, William J. |
description | Two cases are presented illustrating the use of a new intracoronary infusion catheter providing flow support using a unique spiral coil design. Good clinical outcomes were obtained employing 4‐hr inflations with localized infusion of urokinase at the site of dissection and extensive clot formation, respectively. This low‐profile catheter‐mounted device may provide an alternative to stent placement in cases of acute dissection complicated by thrombus formation. © 1995 Wiley‐Liss, Inc. |
doi_str_mv | 10.1002/ccd.1810360118 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_proquest_miscellaneous_77638266</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>77638266</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4078-fbf008252517587679b7071d57d56f5180ff5df23f320da0370d8d6786164403</originalsourceid><addsrcrecordid>eNqFkM1vEzEQxS0EKqFw5YbkA-K2Ybxefyw3tECpVMGBSCAuluOPxrDxbu3dpkX88ThKFMSJ0xze783Mewg9J7AkAPVrY-ySSAKUAyHyAVoQaEUFFJqHaAHQyooz3j5GT3L-AQANp80ZOhONbFkrFuj3ZQxT0D12d6NLwUXj8C5MG6wjDnFK2gxpiDrdY98PO5zncRzShK27DYUc03AbbIjXuB-M7sMvZ7FN83Wx-jmHIb7Bq43D2YTtXgl51JPZYKOnjZtceooeed1n9-w4z9Hqw_tV97G6-nxx2b29qkwDQlZ-7QFkzWpGBJOCi3YtQBDLhGXcMyLBe2Z9TT2twWqgAqy0XEhOeNMAPUevDmvLuzezy5Pahmxc3-vohjkrITiVNecFXB5Ak4ack_NqTGFbwisCat-2Km2rv20Xw4vj5nldEp7wY71Ff3nUdS79-KSjCfmEUc5k0-7vtgdsF3p3_5-jquve_fNCdfCGPLm7k1enn4oLKpj6-ulC0W8dkd-_dKqmfwB7LKg8</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>77638266</pqid></control><display><type>article</type><title>Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter</title><source>MEDLINE</source><source>Wiley Online Library Journals Frontfile Complete</source><creator>Groh, William C. ; Kurnik, Peter B. ; Matthai Jr, William H. ; Untereker, William J.</creator><creatorcontrib>Groh, William C. ; Kurnik, Peter B. ; Matthai Jr, William H. ; Untereker, William J.</creatorcontrib><description>Two cases are presented illustrating the use of a new intracoronary infusion catheter providing flow support using a unique spiral coil design. Good clinical outcomes were obtained employing 4‐hr inflations with localized infusion of urokinase at the site of dissection and extensive clot formation, respectively. This low‐profile catheter‐mounted device may provide an alternative to stent placement in cases of acute dissection complicated by thrombus formation. © 1995 Wiley‐Liss, Inc.</description><identifier>ISSN: 0098-6569</identifier><identifier>EISSN: 1097-0304</identifier><identifier>DOI: 10.1002/ccd.1810360118</identifier><identifier>PMID: 7489597</identifier><identifier>CODEN: CCDIDC</identifier><language>eng</language><publisher>New York: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Aneurysm, Dissecting - diagnostic imaging ; Aneurysm, Dissecting - drug therapy ; Angioplasty, Balloon, Coronary - instrumentation ; Biological and medical sciences ; Blood. Blood coagulation. Reticuloendothelial system ; Catheters, Indwelling ; Combined Modality Therapy ; Coronary Aneurysm - diagnostic imaging ; Coronary Aneurysm - drug therapy ; Coronary Angiography ; Coronary Circulation - drug effects ; Coronary Circulation - physiology ; Coronary Thrombosis - diagnostic imaging ; Coronary Thrombosis - drug therapy ; Equipment Design ; flow support device ; Humans ; Male ; Medical sciences ; Middle Aged ; Pharmacology. Drug treatments ; Recurrence ; Scimed Dispatch Catheter ; thrombolytic therapy ; Thrombolytic Therapy - instrumentation ; Urokinase-Type Plasminogen Activator - administration & dosage ; Urokinase-Type Plasminogen Activator - adverse effects</subject><ispartof>Catheterization and cardiovascular diagnosis, 1995-09, Vol.36 (1), p.67-73</ispartof><rights>Copyright © 1995 John Wiley & Sons, Ltd.</rights><rights>1995 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4078-fbf008252517587679b7071d57d56f5180ff5df23f320da0370d8d6786164403</citedby><cites>FETCH-LOGICAL-c4078-fbf008252517587679b7071d57d56f5180ff5df23f320da0370d8d6786164403</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fccd.1810360118$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fccd.1810360118$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=3658496$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7489597$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Groh, William C.</creatorcontrib><creatorcontrib>Kurnik, Peter B.</creatorcontrib><creatorcontrib>Matthai Jr, William H.</creatorcontrib><creatorcontrib>Untereker, William J.</creatorcontrib><title>Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter</title><title>Catheterization and cardiovascular diagnosis</title><addtitle>Cathet. Cardiovasc. Diagn</addtitle><description>Two cases are presented illustrating the use of a new intracoronary infusion catheter providing flow support using a unique spiral coil design. Good clinical outcomes were obtained employing 4‐hr inflations with localized infusion of urokinase at the site of dissection and extensive clot formation, respectively. This low‐profile catheter‐mounted device may provide an alternative to stent placement in cases of acute dissection complicated by thrombus formation. © 1995 Wiley‐Liss, Inc.</description><subject>Aneurysm, Dissecting - diagnostic imaging</subject><subject>Aneurysm, Dissecting - drug therapy</subject><subject>Angioplasty, Balloon, Coronary - instrumentation</subject><subject>Biological and medical sciences</subject><subject>Blood. Blood coagulation. Reticuloendothelial system</subject><subject>Catheters, Indwelling</subject><subject>Combined Modality Therapy</subject><subject>Coronary Aneurysm - diagnostic imaging</subject><subject>Coronary Aneurysm - drug therapy</subject><subject>Coronary Angiography</subject><subject>Coronary Circulation - drug effects</subject><subject>Coronary Circulation - physiology</subject><subject>Coronary Thrombosis - diagnostic imaging</subject><subject>Coronary Thrombosis - drug therapy</subject><subject>Equipment Design</subject><subject>flow support device</subject><subject>Humans</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Pharmacology. Drug treatments</subject><subject>Recurrence</subject><subject>Scimed Dispatch Catheter</subject><subject>thrombolytic therapy</subject><subject>Thrombolytic Therapy - instrumentation</subject><subject>Urokinase-Type Plasminogen Activator - administration & dosage</subject><subject>Urokinase-Type Plasminogen Activator - adverse effects</subject><issn>0098-6569</issn><issn>1097-0304</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1995</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNqFkM1vEzEQxS0EKqFw5YbkA-K2Ybxefyw3tECpVMGBSCAuluOPxrDxbu3dpkX88ThKFMSJ0xze783Mewg9J7AkAPVrY-ySSAKUAyHyAVoQaEUFFJqHaAHQyooz3j5GT3L-AQANp80ZOhONbFkrFuj3ZQxT0D12d6NLwUXj8C5MG6wjDnFK2gxpiDrdY98PO5zncRzShK27DYUc03AbbIjXuB-M7sMvZ7FN83Wx-jmHIb7Bq43D2YTtXgl51JPZYKOnjZtceooeed1n9-w4z9Hqw_tV97G6-nxx2b29qkwDQlZ-7QFkzWpGBJOCi3YtQBDLhGXcMyLBe2Z9TT2twWqgAqy0XEhOeNMAPUevDmvLuzezy5Pahmxc3-vohjkrITiVNecFXB5Ak4ack_NqTGFbwisCat-2Km2rv20Xw4vj5nldEp7wY71Ff3nUdS79-KSjCfmEUc5k0-7vtgdsF3p3_5-jquve_fNCdfCGPLm7k1enn4oLKpj6-ulC0W8dkd-_dKqmfwB7LKg8</recordid><startdate>199509</startdate><enddate>199509</enddate><creator>Groh, William C.</creator><creator>Kurnik, Peter B.</creator><creator>Matthai Jr, William H.</creator><creator>Untereker, William J.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199509</creationdate><title>Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter</title><author>Groh, William C. ; Kurnik, Peter B. ; Matthai Jr, William H. ; Untereker, William J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4078-fbf008252517587679b7071d57d56f5180ff5df23f320da0370d8d6786164403</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1995</creationdate><topic>Aneurysm, Dissecting - diagnostic imaging</topic><topic>Aneurysm, Dissecting - drug therapy</topic><topic>Angioplasty, Balloon, Coronary - instrumentation</topic><topic>Biological and medical sciences</topic><topic>Blood. Blood coagulation. Reticuloendothelial system</topic><topic>Catheters, Indwelling</topic><topic>Combined Modality Therapy</topic><topic>Coronary Aneurysm - diagnostic imaging</topic><topic>Coronary Aneurysm - drug therapy</topic><topic>Coronary Angiography</topic><topic>Coronary Circulation - drug effects</topic><topic>Coronary Circulation - physiology</topic><topic>Coronary Thrombosis - diagnostic imaging</topic><topic>Coronary Thrombosis - drug therapy</topic><topic>Equipment Design</topic><topic>flow support device</topic><topic>Humans</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Pharmacology. Drug treatments</topic><topic>Recurrence</topic><topic>Scimed Dispatch Catheter</topic><topic>thrombolytic therapy</topic><topic>Thrombolytic Therapy - instrumentation</topic><topic>Urokinase-Type Plasminogen Activator - administration & dosage</topic><topic>Urokinase-Type Plasminogen Activator - adverse effects</topic><toplevel>online_resources</toplevel><creatorcontrib>Groh, William C.</creatorcontrib><creatorcontrib>Kurnik, Peter B.</creatorcontrib><creatorcontrib>Matthai Jr, William H.</creatorcontrib><creatorcontrib>Untereker, William J.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Catheterization and cardiovascular diagnosis</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Groh, William C.</au><au>Kurnik, Peter B.</au><au>Matthai Jr, William H.</au><au>Untereker, William J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter</atitle><jtitle>Catheterization and cardiovascular diagnosis</jtitle><addtitle>Cathet. Cardiovasc. Diagn</addtitle><date>1995-09</date><risdate>1995</risdate><volume>36</volume><issue>1</issue><spage>67</spage><epage>73</epage><pages>67-73</pages><issn>0098-6569</issn><eissn>1097-0304</eissn><coden>CCDIDC</coden><abstract>Two cases are presented illustrating the use of a new intracoronary infusion catheter providing flow support using a unique spiral coil design. Good clinical outcomes were obtained employing 4‐hr inflations with localized infusion of urokinase at the site of dissection and extensive clot formation, respectively. This low‐profile catheter‐mounted device may provide an alternative to stent placement in cases of acute dissection complicated by thrombus formation. © 1995 Wiley‐Liss, Inc.</abstract><cop>New York</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><pmid>7489597</pmid><doi>10.1002/ccd.1810360118</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0098-6569 |
ispartof | Catheterization and cardiovascular diagnosis, 1995-09, Vol.36 (1), p.67-73 |
issn | 0098-6569 1097-0304 |
language | eng |
recordid | cdi_proquest_miscellaneous_77638266 |
source | MEDLINE; Wiley Online Library Journals Frontfile Complete |
subjects | Aneurysm, Dissecting - diagnostic imaging Aneurysm, Dissecting - drug therapy Angioplasty, Balloon, Coronary - instrumentation Biological and medical sciences Blood. Blood coagulation. Reticuloendothelial system Catheters, Indwelling Combined Modality Therapy Coronary Aneurysm - diagnostic imaging Coronary Aneurysm - drug therapy Coronary Angiography Coronary Circulation - drug effects Coronary Circulation - physiology Coronary Thrombosis - diagnostic imaging Coronary Thrombosis - drug therapy Equipment Design flow support device Humans Male Medical sciences Middle Aged Pharmacology. Drug treatments Recurrence Scimed Dispatch Catheter thrombolytic therapy Thrombolytic Therapy - instrumentation Urokinase-Type Plasminogen Activator - administration & dosage Urokinase-Type Plasminogen Activator - adverse effects |
title | Initial experience with an intracoronary flow support device providing localized drug infusion: The scimed dispatch catheter |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-23T05%3A45%3A19IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Initial%20experience%20with%20an%20intracoronary%20flow%20support%20device%20providing%20localized%20drug%20infusion:%20The%20scimed%20dispatch%20catheter&rft.jtitle=Catheterization%20and%20cardiovascular%20diagnosis&rft.au=Groh,%20William%20C.&rft.date=1995-09&rft.volume=36&rft.issue=1&rft.spage=67&rft.epage=73&rft.pages=67-73&rft.issn=0098-6569&rft.eissn=1097-0304&rft.coden=CCDIDC&rft_id=info:doi/10.1002/ccd.1810360118&rft_dat=%3Cproquest_cross%3E77638266%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=77638266&rft_id=info:pmid/7489597&rfr_iscdi=true |