Performance of ultrasonic speckle tracking in various tissues

The purpose of this study was to investigate the accuracy of ultrasound speckle tracking in various tissues. Results from two-dimensional tissue speckle tracking in liver, muscle, fat, and sponge samples are presented, while keeping other speckle tracking parameters constant. Speckle tracking perfor...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of the Acoustical Society of America 1995-09, Vol.98 (3), p.1273-1278
Hauptverfasser: Chen, E J, Jenkins, W K, O'Brien, Jr, W D
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:The purpose of this study was to investigate the accuracy of ultrasound speckle tracking in various tissues. Results from two-dimensional tissue speckle tracking in liver, muscle, fat, and sponge samples are presented, while keeping other speckle tracking parameters constant. Speckle tracking performance was characterized both in terms of the magnitude of tracking errors and in terms of the percentage of correctly tracked displacement vectors. Speckle tracking in muscle tissue, which contains myofibrils and significant tissue microstructure, produced the highest percentage of correctly tracked vectors and smallest tracking errors relative to other tissues.
ISSN:0001-4966
1520-8524
DOI:10.1121/1.414453