Intravascular ultrasound predictors of outcome after peripheral balloon angioplasty

This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery. Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 3...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European journal of vascular and endovascular surgery 1995-10, Vol.10 (3), p.279-288
Hauptverfasser: Gussenhoven, Elma J., van der Lugt, Aad, Pasterkamp, Gerard, van den Berg, Fred G., Sie, Lewi H., Vischjager, Manfred, The, Salem H.K., Li, Wenguang, Pieterman, Herman, van Urk, Hero
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This study investigates the potential role of intravascular ultrasound (IVUS) in the outcome in patients undergoing percutaneous transluminal angioplasty (PTA) of the superficial femoral artery. Angiographic and the qualitative and quantitative IVUS data obtained at the narrowest site derived from 39 patients before and after PTA were analysed. Angiographically the diameter of the remaining stenosis seen after PTA was classified as < 50% in 31 patients (success); in eight patients a failure was encountered. Evaluating at 6 months the functional and anatomic results of the PTA in 31 patients, the intervention was a success in 14 patients (Group I) and a failure in 17 patients (Group II). The remaining eight patients defined as angiographic failure following PTA comprised Group III. Neither qualitative nor quantitative IVUS data obtained before PTA could predict outcome. Conversely, after PTA, the extent of dissection was significantly more severe in Groups II and III than in Group I. Similarly, significant differences were found between Groups I and II for mean free lumen area (13.2 vs. 9.7 mm 2, respectively) and mean free lumen diameter (4.1 vs. 3.5 mm, respectively). Quantitative data obtained in Group II were similar to those in Group III. This preliminary study demonstrates that following PTA the extent of dissection, free lumen area and diameter seen with IVUS are predictive factors of patency. Future studies with more patients are mandatory to further highlight the sensitivity of these observations.
ISSN:1078-5884
1532-2165
DOI:10.1016/S1078-5884(05)80043-7