Complications and Failures of Subclavian-Vein Catheterization
To the Editor: Mansfield et al. (Dec. 29 issue) 1 found that ultrasound-guided location of the subclavian vein was not beneficial, as compared with standard insertion procedures for subclavian-vein catheterization. The authors used ultrasound only to mark the site of insertion and did not study real...
Gespeichert in:
Veröffentlicht in: | The New England journal of medicine 1995-06, Vol.332 (23), p.1579-1581 |
---|---|
Hauptverfasser: | , , , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To the Editor:
Mansfield et al. (Dec. 29 issue)
1
found that ultrasound-guided location of the subclavian vein was not beneficial, as compared with standard insertion procedures for subclavian-vein catheterization. The authors used ultrasound only to mark the site of insertion and did not study real-time ultrasound guidance of catheter placement. We believe that real-time ultrasound guidance might have been beneficial because of the favorable findings of another study
2
and the reported success with ultrasound guidance of internal jugular-vein catheterization.
3
–
5
A simple mark on the skin does not indicate the axis that will engage the vessel. The deeper the structure, . . . |
---|---|