A comparative diagnostic study of head and neck nodal metastases using positron emission tomography

A prospective study was conducted to compare the accuracy of clinical examination, computed tomography (CT), and positron emission tomography (PET) in identifying head and neck squamous cell carcinoma metastatic to cervical lymph nodes. The findings in the necks of 49 patients evaluated by clinical...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Laryngoscope 1995-04, Vol.105 (4), p.373-375
Hauptverfasser: McGuirt, W. Frederick, Williams III, Daniel W., Keyes Jr, John W., Greven, Kathryn M., Watson Jr, Nat E., Geisinger, Kim R., Cappellari, James O.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A prospective study was conducted to compare the accuracy of clinical examination, computed tomography (CT), and positron emission tomography (PET) in identifying head and neck squamous cell carcinoma metastatic to cervical lymph nodes. The findings in the necks of 49 patients evaluated by clinical examination and CT were compared to the findings in the same necks by PET, a newly available metabolic imaging modality. Pathology specimens were available for 45 of the necks. The findings of PET and CT correlated in 84% of cases. In the cases that did not correlate, CT proved correct in four of five cases. PET (82%) and CT (84%) were comparable and were both better than clinical examination (71%) in correctly identifying the presence or absence of metastatic disease.
ISSN:0023-852X
1531-4995
DOI:10.1288/00005537-199504000-00006