A comparison of build-up and depth dose characteristics of different photon beams for the treatment of Hodgkin's disease
Measurements have been performed of build-up and depth-dose characteristics of photon beams under Hodgkin's disease treatment conditions as applied in two hospitals (AVL, Amsterdam and IGR, Villejuif). Although different types of accelerators, photon energies, field sizes and SSD are employed,...
Gespeichert in:
Veröffentlicht in: | Radiotherapy and oncology 1986, Vol.6 (4), p.301-307 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Measurements have been performed of build-up and depth-dose characteristics of photon beams under Hodgkin's disease treatment conditions as applied in two hospitals (AVL, Amsterdam and IGR, Villejuif). Although different types of accelerators, photon energies, field sizes and SSD are employed, similar dose distributions along the beam axis have been obtained in both centers. In order to explain this unexpected good agreement, the influence of the geometrical conditions of irradiation on the build-up and depth-dose distribution has been studied in detail for five photon beams (8 MV-25 MV) of three types of accelerators. |
---|---|
ISSN: | 0167-8140 1879-0887 |
DOI: | 10.1016/S0167-8140(86)80197-9 |