Vitamin A and E status in very low birth weight infants: Development of an improved parenteral delivery system
Plasma vitamin A and E levels were inadequate in very low birth weight infants receiving a continuous infusion of a parenteral multivitamin preparation, 1.5 ml/kg per day, in dextrose-amino acid solution. A new delivery system using 2 ml/kg per day, infused for 6 hours from the first day of life, av...
Gespeichert in:
Veröffentlicht in: | The Journal of pediatrics 1995, Vol.126 (1), p.128-131 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Plasma vitamin A and E levels were inadequate in very low birth weight infants receiving a continuous infusion of a parenteral multivitamin preparation, 1.5 ml/kg per day, in dextrose-amino acid solution. A new delivery system using 2 ml/kg per day, infused for 6 hours from the first day of life, avoided loss during infusion and significantly improved plasma vitamin A and E levels during the first 28 days of life in very low birth weight infants. (J P
EDIATR 1995;126:128-31) |
---|---|
ISSN: | 0022-3476 1097-6833 |
DOI: | 10.1016/S0022-3476(95)70515-5 |