Vitamin A and E status in very low birth weight infants: Development of an improved parenteral delivery system

Plasma vitamin A and E levels were inadequate in very low birth weight infants receiving a continuous infusion of a parenteral multivitamin preparation, 1.5 ml/kg per day, in dextrose-amino acid solution. A new delivery system using 2 ml/kg per day, infused for 6 hours from the first day of life, av...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of pediatrics 1995, Vol.126 (1), p.128-131
Hauptverfasser: Inder, T.E., Carr, A.C., Winterbourn, C.C., Austin, N.C., Darlow, B.A.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Plasma vitamin A and E levels were inadequate in very low birth weight infants receiving a continuous infusion of a parenteral multivitamin preparation, 1.5 ml/kg per day, in dextrose-amino acid solution. A new delivery system using 2 ml/kg per day, infused for 6 hours from the first day of life, avoided loss during infusion and significantly improved plasma vitamin A and E levels during the first 28 days of life in very low birth weight infants. (J P EDIATR 1995;126:128-31)
ISSN:0022-3476
1097-6833