Prospective Study of Catheter Replacement and Other Risk Factors for Infection of Hyperalimentation Catheters
To determine risk factors for infection of hyperalimentation catheters, we prospectively studied 169 catheter systems (88 patients) by using a semiquantitative culture technique. Infection occurred in 24 (14%) catheters (16 patients), was inversely proportional to the number of previous catheters in...
Gespeichert in:
Veröffentlicht in: | The Journal of infectious diseases 1986-11, Vol.154 (5), p.808-816 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | To determine risk factors for infection of hyperalimentation catheters, we prospectively studied 169 catheter systems (88 patients) by using a semiquantitative culture technique. Infection occurred in 24 (14%) catheters (16 patients), was inversely proportional to the number of previous catheters inserted by the operator (P < .02), and was proportional to the interval between admission and catheter insertion (P < .0005). Catheter replacement over a guidewire was no more likely to be associated with infection than was a de novo percutaneous insertion at another site (P = .6). Using a proportional hazards model, we estimated the risk of infection per day to be 1.3 times greater for a catheter if the patient had been hospitalized 50 days instead of seven days, and 3.8 times greater if the patient had a Swan-Ganz catheter at the time of insertion. |
---|---|
ISSN: | 0022-1899 1537-6613 |
DOI: | 10.1093/infdis/154.5.808 |