Human cardiovascular and vestibular responses in long minutes and low +Gz loading by a short arm centrifuge
1.4 G, 1.7 G, and 2.0 G of +Gz and 60 minutes centrifugation was adopted to 20 healthy male subjects using 1.8 m radius centrifuge equipped to Nihon University School of Medicine. G was applied from lower G, considering G training effect for the subjects. Effects on performance decline and side effe...
Gespeichert in:
Veröffentlicht in: | Acta astronautica 1994-07, Vol.33, p.239-252 |
---|---|
Hauptverfasser: | , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | 1.4 G, 1.7 G, and 2.0 G of +Gz and 60 minutes centrifugation was adopted to 20 healthy male subjects using 1.8 m radius centrifuge equipped to Nihon University School of Medicine. G was applied from lower G, considering G training effect for the subjects. Effects on performance decline and side effects of such a short-arm centrifugation were especially observed in the experiments, because this size of centrifuge could be used in space station in future for a strong countermeasure of cardiovascular deconditioning, demineralization from bone, etc. G training effect was observed same as higher and rapid G acceleration in fighter pilot. Subjects suffered from many types of discomfort; such as sensation of heaviness of diaphragm, cold sweat, nausea, irritable feeling, arrhythmia, tachycardia, rapid decrease of blood pressure, which sometimes caused interruption of G load. As 2.0 G and 60 minutes centrifugation seemed very tough load to the subjects, there should be necessary some G suit or other countermeasure, if we apply a higher G and/or longer G duration. Performance decline due to the load commonly continued for 1 hour or so. Side effects were observed in relation to neuro-vestibular, cardio-vascular, and autonomic nervous system. |
---|---|
ISSN: | 0094-5765 1879-2030 |
DOI: | 10.1016/0094-5765(94)90131-7 |