Fixation of Periprosthetic Femoral Shaft Fractures: A Biomechanical Comparison of Two Techniques
OBJECTIVETo determine which of two currently used techniques for the treatment of periprosthetic femoral shaft fractures provides the greater fixation rigidity and strength. DESIGN A laboratory study using six matched pairs of femurs. METHODSEmbalmed femur prosthesis constructs had a simulated perip...
Gespeichert in:
Veröffentlicht in: | Journal of orthopaedic trauma 2001-03, Vol.15 (3), p.177-180 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | OBJECTIVETo determine which of two currently used techniques for the treatment of periprosthetic femoral shaft fractures provides the greater fixation rigidity and strength.
DESIGN A laboratory study using six matched pairs of femurs.
METHODSEmbalmed femur prosthesis constructs had a simulated periprosthetic fracture created and were fixed with a plate with proximal cables and distal bicortical screws (Ogden concept) or two allograft struts and cables. Fixation stability was compared in various loading modalities before and after cycling. They were then tested to failure.
OUTCOME MEASUREMENTSFixation rigidity was defined as the ratio of applied load to the amount of displacement at the fracture.
RESULTSIn all loading modalities, the Ogden construct was more rigid than the allograft strut fixation. The Ogden construct required 1,295 newtons for failure and the allograft strut fixation required 950 newtons (p < 0.05).
CONCLUSIONThe Ogden construct provided a more rigid and stronger initial fixation of a periprosthetic fracture than did the allograft construct. |
---|---|
ISSN: | 0890-5339 1531-2291 |