Management of acute cardiac failure with mechanical assist: experience with the ABIOMED BVS 5000

Background. Mechanical circulatory assist industries have developed ventricular assist devices (VAD) for short-, intermediate-, and long-term use. The purpose of this report is to describe the progress made with the ABIOMED Biventricular System (BVS) 5000 (ABIOMED, Inc, Danvers, MA) short-term VAD....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Annals of thoracic surgery 2001-03, Vol.71 (3), p.S67-S72
Hauptverfasser: Samuels, Louis E, Holmes, Elena C, Thomas, Matthew P, Entwistle, John C, Morris, Rohinton J, Narula, Jaguat, Wechsler, Andrew S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Background. Mechanical circulatory assist industries have developed ventricular assist devices (VAD) for short-, intermediate-, and long-term use. The purpose of this report is to describe the progress made with the ABIOMED Biventricular System (BVS) 5000 (ABIOMED, Inc, Danvers, MA) short-term VAD. Methods. From June 1994 through August 2000, all cardiogenic shock patients who required short-term mechanical assist were supported with the ABIOMED BVS 5000. Insertion criteria included any condition that may potentially result in cardiac recovery. A formal algorithm for timing of insertion was established to standardize implantation criteria. Results. A total of 45 patients were supported at Hahnemann University Hospital, Philadelphia, PA. There were 26 male and 19 female patients, with a mean age of 57.9 years (range 33 to 80 years). Devices were inserted for postcardiotomy shock in 36 patients (80%) and precardiotomy shock in 9 patients (20%). The average duration of support was 8.3 days (range 1 to 31 days). Overall, there were 22 (49%) patients weaned from support and 14 (31%) discharged from the hospital. For patients in whom the device was implanted in accordance with an established protocol (group A), the wean and discharge rates were 60% and 43%, respectively. The most common morbidities included bleeding and adverse neurologic events. Conclusions. The ABIOMED BVS 5000 VAD continues to be a valuable form of short-term mechanical assist for acute cardiogenic shock. The formation of a uniform VAD insertion algorithm has helped to standardize protocols in management.
ISSN:0003-4975
1552-6259