Bifid median nerve compression due to a musculotendinous anomaly of FDS to the middle finger

A case is presented of a bifid median nerve whose longest portion had a normal course while the other portion passed through a hole in the FDS tendon of the middle finger, at its musculotendinous junction. This caused nerve compression during muscle contraction, producing pain and dysaesthesia in th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of hand surgery, British volume British volume, 1994-10, Vol.19 (5), p.616-617
Hauptverfasser: Fernandez-Garcia, S., Pi-Folguera, J., Estallo-Matino, F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A case is presented of a bifid median nerve whose longest portion had a normal course while the other portion passed through a hole in the FDS tendon of the middle finger, at its musculotendinous junction. This caused nerve compression during muscle contraction, producing pain and dysaesthesia in the middle finger suggesting carpal tunnel syndrome.
ISSN:0266-7681
1532-2211
DOI:10.1016/0266-7681(94)90128-7