Determination of the Normal Range of Furosemide Half-Clearance Times When Using Tc-99m MAG3
In radionuclide diuresis renography, furosemide half-clearance times have been established using Tc-99m DTPA but have not been verified when Tc-99m MAG3 is used. One hundred and six consecutive diuretic renograms using Tc-99m MAG3 for the evaluation of unilateral renal abnormalities were assessed. T...
Gespeichert in:
Veröffentlicht in: | Clinical nuclear medicine 1994-10, Vol.19 (10), p.880-882 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | In radionuclide diuresis renography, furosemide half-clearance times have been established using Tc-99m DTPA but have not been verified when Tc-99m MAG3 is used. One hundred and six consecutive diuretic renograms using Tc-99m MAG3 for the evaluation of unilateral renal abnormalities were assessed. The furosemide half-clearance times of the normal kidneys were all less than 9.8 minutes, with a mean of 3.4 minutes. In 18 patients, the half-clearance times of the normal kidney were artificially prolonged because urine had drained before the administration of the diuretic. The normal furosemide half-clearance time values obtained using Tc-99m MAG3 were found to be similar to those established for Tc-99m DTPA. Prolonged half-clearance times of Tc-99m MAG3 must be confirmed by visual evidence of obstruction. |
---|---|