Use of E-speed film with added filtration
The use of aluminum, gadolinium, and yttrium filters in conjunction with E-speed film was studied. The resulting radiographs were judged to be acceptable for diagnostic purposes, although clinicians showed a preference for E-speed radiographs made at reduced exposure times and for D-speed radiograph...
Gespeichert in:
Veröffentlicht in: | Oral surgery, oral medicine, oral pathology oral medicine, oral pathology, 1986-03, Vol.61 (3), p.297-299 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The use of aluminum, gadolinium, and yttrium filters in conjunction with E-speed film was studied. The resulting radiographs were judged to be acceptable for diagnostic purposes, although clinicians showed a preference for E-speed radiographs made at reduced exposure times and for D-speed radiographs. There was no detectable difference between the radiographs produced with the various filter materials. |
---|---|
ISSN: | 0030-4220 1878-2175 |
DOI: | 10.1016/0030-4220(86)90378-6 |