An improved HPLC method to purify erythrocyte cholesterol for estimation of in vivo cholesterol synthesis using the deuterium method
We report on an improved HPLC method to purify erythrocyte cholesterol for use in measuring in vivo cholesterol synthesis from 2H 2O. The new procedure uses a smaller compression cartridge column at a flow rate of 3 mL/min. The new method reduces by almost tenfold the amount of solvent required to m...
Gespeichert in:
Veröffentlicht in: | Applied radiation and isotopes 1994-04, Vol.45 (4), p.529-533 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | We report on an improved HPLC method to purify erythrocyte cholesterol for use in measuring
in vivo cholesterol synthesis from
2H
2O. The new procedure uses a smaller compression cartridge column at a flow rate of 3 mL/min. The new method reduces by almost tenfold the amount of solvent required to maintain the analytical purity of the isolated cholesterol. |
---|---|
ISSN: | 0969-8043 1872-9800 |
DOI: | 10.1016/0969-8043(94)90121-X |