Failure of the colloid oncotic-pulmonary artery wedge pressure gradient to predict changes in extravascular lung water
Colloid oncotic pressure (COP), pulmonary artery wedge pressure (WP), and the COP-WP gradient were measured in seven critically ill adult patients and compared with extravascular lung water determined using the thermal-dye double-indicator dilution technique and a bedside lung water computer. Correl...
Gespeichert in:
Veröffentlicht in: | Critical care medicine 1985-12, Vol.13 (12), p.1025-1028 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Colloid oncotic pressure (COP), pulmonary artery wedge pressure (WP), and the COP-WP gradient were measured in seven critically ill adult patients and compared with extravascular lung water determined using the thermal-dye double-indicator dilution technique and a bedside lung water computer. Correlation coefficients for changes in extravascular lung water vs. COP, WP, and COP-WP were not significant, and in this patient population the COP-WP gradient did not predict changes in extravascular lung water. |
---|---|