Kinetic Modeling of Teboroxime Using Dynamic SPECT Imaging of a Canine Model
The tomographic utility of 99mTc-labeled teboroxime has been limited because of its fast washout from the heart, which requires rapid data acquisitions that have not been feasible until the recent development of multidetector SPECT systems. Using a three-detector SPECT system to acquire dynamic tomo...
Gespeichert in:
Veröffentlicht in: | The Journal of nuclear medicine (1978) 1994-03, Vol.35 (3), p.484-495 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The tomographic utility of 99mTc-labeled teboroxime has been limited because of its fast washout from the heart, which requires rapid data acquisitions that have not been feasible until the recent development of multidetector SPECT systems.
Using a three-detector SPECT system to acquire dynamic tomographic data every 10.2 sec, we investigated the potential of modeling the kinetics of teboroxime to develop a sensitive and quantitative measure of cardiac perfusion. Seven studies were performed on four dogs; in three of the studies the LAD artery was occluded. The three-dimensional activity distributions were reconstructed and were corrected for attenuation using a transmission scan. Time-activity curves from the blood and tissue were fit to a two-compartment model with two-way exchange.
Performing attenuation correction during the reconstruction process affected the washin parameter k21 significantly (p < 0.0001). The washin parameter k21 also decreased significantly (p < 0.002) when the LAD was occluded.
The results indicate that the washin of teboroxime in myocardial tissue (k21) measured using dynamic SPECT imaging and kinetic modeling is an indicator of myocardial blood flow. |
---|---|
ISSN: | 0161-5505 1535-5667 |