Cortical thermal clearance monitoring in surgery for a giant middle cerebral artery aneurysm
Cortical thermal clearance was used during surgery for clipping of a giant middle cerebral artery (MCA) aneurysm. During prolonged continuous proximal MCA occlusion thermal clearance remained normal, indicating sufficient collateral blood supply. Postoperatively the patient had no neurological defic...
Gespeichert in:
Veröffentlicht in: | British journal of neurosurgery 1993, Vol.7 (6), p.673-676 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Cortical thermal clearance was used during surgery for clipping of a giant middle cerebral artery (MCA) aneurysm. During prolonged continuous proximal MCA occlusion thermal clearance remained normal, indicating sufficient collateral blood supply. Postoperatively the patient had no neurological deficit. This monitoring technique is a useful guide to the safety of temporary clipping during aneurysm surgery. |
---|---|