Factors affecting sliding of the lag screw in intertrochanteric fractures

A retrospective study of 76 intertrochanteric fractures was undertaken to evaluate the failures of fixation. In every case anatomical reduction was attempted, and 135 degrees sliding compression screws and plates were used for fixation. In 2 cases, the screw penetrated into the joint and there were...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International orthopaedics 1993-11, Vol.17 (5), p.320-324
Hauptverfasser: RHA, J. D, KIM, Y. H, YOON, S. I, PARK, T. S, LEE, M. H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:A retrospective study of 76 intertrochanteric fractures was undertaken to evaluate the failures of fixation. In every case anatomical reduction was attempted, and 135 degrees sliding compression screws and plates were used for fixation. In 2 cases, the screw penetrated into the joint and there were 8 cases where there was excessive sliding of the implant. These complications were only found in unstable fractures. They occurred most frequently in elderly patients, and when the distal fragment was displaced medially and anteriorly.
ISSN:0341-2695
1432-5195
DOI:10.1007/BF00181709