Analysis of hydrocyclone behaviors in the separation of particulates from highway rainfall runoff

In this study, the separation behaviors of particles in highway rainfall runoff using a Ø7.5 cm hydrocyclone were examined. The volume fraction and the total suspended solids concentrations in the overflow and underflow from the hydrocyclone were analyzed. The results indicated that the overflow vol...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Water science and technology 2010-01, Vol.62 (3), p.532-540
Hauptverfasser: Yu, Jianghua, Yi, Qitao, Kim, Youngchul, Tateda, Masafumi
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:In this study, the separation behaviors of particles in highway rainfall runoff using a Ø7.5 cm hydrocyclone were examined. The volume fraction and the total suspended solids concentrations in the overflow and underflow from the hydrocyclone were analyzed. The results indicated that the overflow volume fraction increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes (D(u)/D(i)), while the underflow volume fraction showed contrary behavior. The TSS concentration ratio between the overflow and inflow (TSS(over)/TSS(in)) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow (TSS(under)/TSS(in)) increased. There was no visible difference in the TSS(over)/TSS(in) ratio with increasing D(u)/D(i) ratio but the TSS(under)/TSS(in) decreased sharply. The particle removal efficiency was affected mainly by the particle size. The hydrocyclone can work well using 1.6 m natural water head, and it is more space saving and more efficient in the separation of fine particles than the sedimentation method.
ISSN:0273-1223
1996-9732
DOI:10.2166/wst.2010.143