Dislocation following primary posterior-stabilized total knee arthroplasty

From 1981 through 1991, 3, 032 primary total knee arthroplasties were performed using the Insall-Burstein Posterior Stabilized Condylar Prosthesis (IB-I, IB-II, and IB-II modified) (Zimmer, Warsaw, IN). Fifteen posterior dislocations occurred: 4 with the IB-I system occurring 2 or more years after s...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of arthroplasty 1993, Vol.8 (6), p.633-639
Hauptverfasser: Lombardi, Adolph V., Mallory, Thomas H., Vaughn, Bradley K., Krugel, Richard, Honkala, Timothy K., Sorscher, Michael, Kolczun, Michael
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:From 1981 through 1991, 3, 032 primary total knee arthroplasties were performed using the Insall-Burstein Posterior Stabilized Condylar Prosthesis (IB-I, IB-II, and IB-II modified) (Zimmer, Warsaw, IN). Fifteen posterior dislocations occurred: 4 with the IB-I system occurring 2 or more years after surgery, 10 with the IB-II system (8 occurring 6 months after surgery and 2 occurring 2–3 years after surgery), and 1 with the IB-II modified system occurring 9 months after surgery. Statistically significant differences for the rate of dislocation between both the IB-I and IB-II modified arthroplasties versus the IB-II arthroplasties were found ( P < .001). In an attempt to identify a cause for these dislocations, the authors retrospectively assessed the 15 dislocated cases with respect to sex, age, weight, height, preoperative and postoperative Hospital for Special Surgery scores, preoperative and postoperative alignment, preoperative versus postoperative reconstruction dimensions, patellar thickness and height, and postoperative flexion and compared the results with those patients who did not experience dislocation. Possible etiologies and mechanisms of dislocation were sought. There were no significant differences between the control and study groups for any variable assessed, with the exception of postoperative flexion, which averaged 118° for the study group and 105° for the control group ( P < .001). Conservative management was successful in 11 cases. In September 1988 the IB-II system was introduced; modification of the tibial insert was made in January 1990. The 10 IB-II dislocations occurred prior to the modification of the modular tibial polyethylene insert, and the 3 recurrent dislocations in this group were successfully treated with revision to this modified insert. Since this modification, 656 IB-II modified systems have been implanted with one dislocation (0.15%).
ISSN:0883-5403
1532-8406
DOI:10.1016/0883-5403(93)90012-S