Quantitative ascending aortic Doppler blood velocity in normal human subjects

We have developed digital, Apple II microcomputer-based methods for the numerical analysis of pulsed, range-gated, ultrasonic Doppler blood velocity signals. These methods were then used to analyse Doppler data recorded every 5 ms from the ascending aorta via the suprasternal notch in normal subject...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Cardiovascular research 1985-07, Vol.19 (7), p.383-393
Hauptverfasser: LEVY, BERNARD, TARGETT, RALPH C, BARDOU, ALAIN, McILROY, MALCOLM B
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We have developed digital, Apple II microcomputer-based methods for the numerical analysis of pulsed, range-gated, ultrasonic Doppler blood velocity signals. These methods were then used to analyse Doppler data recorded every 5 ms from the ascending aorta via the suprasternal notch in normal subjects ranging in age from 3 to 62 years. Normal values for peak velocity, the integral of velocity over the time of systole, and the rate of change of velocity in early ejection are reported. It was found that, after an initial step increase, the velocity of blood flow in early ejection increased in a linear manner in more than two thirds of the individual beats analysed. The time for which the linear acceleration in the aorta was constant (circa 50 ms) was unrelated to the age or size of the subject.
ISSN:0008-6363
1755-3245
DOI:10.1093/cvr/19.7.383